The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to. à aiguille interne. STANDARD. ISO. Second edition. Reference number. ISO (E). Provläsningsexemplar / Preview. STANDARD. ISO. Second edition. Reference number. ISO (E). This is a free 4 page sample. Access the full version online.

Author: Nikorn Vugore
Country: Lesotho
Language: English (Spanish)
Genre: Science
Published (Last): 28 October 2012
Pages: 266
PDF File Size: 9.65 Mb
ePub File Size: 7.23 Mb
ISBN: 169-4-61071-696-6
Downloads: 86473
Price: Free* [*Free Regsitration Required]
Uploader: Shaktim

When tested in accordance with annex E, fluid shall not leak out of the vent fitting within 15 s. NOTE To improve the visibility of the solution, a colorant such as red or blue food dye may be incorporated.

Details of which is given in National Annex A.

At the time of publication, the editions indicated were valid. Fixed or removable fitting per- mitting venting of air while restricting or preferably preventing the escape of blood.

I Principle A force is applied successively tensile and connpress- ive to the needle tube and needle hub and the tube- hub union is then examined for loosening. Pages 1 and 2 4.

Measure the time taken for fluid to form the first falling drop at the back of the vent fitting. This does not preclude the free use, in the course of implementing the standard, of necessary details, such as symbols and sizes, type or grade designations. The details of conditions under which the licence for the use of the Standard Mark may be granted to manufacturers or producers may be obtained from the Bureau of Indian Standards.

Designation and catalogue of CCR colours. Until that time, a manufacturer may label his product “radio- opaque” provided he can support this claim by demonstrat- ing that he has an appropriate method for showing radio- opacity.

Limited collection of colours.

  A MODERN INTRODUCTION TO QUANTUM FIELD THEORY MICHELE MAGGIORE PDF

EN ISO – European Standards

Annex D shows examples of typical needle point geom- etries. Standards are also reviewed periodically; a standard alongwith amendments is reaffirmed when such review indicates that no changes are needed; if the review indicates that changes are needed, it is taken up for revision.

The catheter tube ieo have a single lumen or multiple lumens. The corresponding Indian Standards which are to be substituted in their isoo are listed below along with their degree of equivalence for the editions indicated: International Standard ISO Review of Indian Standards Amendments are issued to standards as the need arises on the basis of comments.

Copyright BIS has the copyright of all its publications. E-5 Test report The test report shall contain at least the following information: Bureau of Indian Standards BIS is a statutory institution established under the Bureau of Indian Standards Act, to promote harmonious development of the activities of standardization, marking and quality certification of goods and attending to connected matters in the country.

Catheter designed for the introduction or withdrawal of liquids or devices into or from the peripheral vascular system. The assembly comprising at least a needle tube attached to and communicating with a needle hub.

CSN EN ISO 10555-5

For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated expressing the result of a test or analysis, shall be rounded off in accordance with IS 2: I Iao Water is allowed to flow through the catheter and the amount of flow is measured either volumetrically or gravimetrically. Available from Munsell Color, N. Page 3, subclause 4.

Fitting attached to the needle tube, providing communication with its bore. An approved test method for producing a value of radio-detectability will be established. Figure 1 — Typical over-needle peripheral intravascular catheter NOTE 2 At the time of publication of this part of ISOthere is 10555-5 acceptable, validated test method to determine radio-detectability. No part of the these publications may be reproduced in any form without the prior permission in writing of BIS.

  LOXOSCELISMO TRATAMIENTO PDF

Part 1 General requirements do The technical committee has reviewed the provisions of the following International 100555-5 referred 105555-5 this adopted standard and has decided that it is acceptable for oso in conjunction with this standard: The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard.

Peripheral intravascular catheter designed for the introduction of withdrawal of liquids or devices into or from the peripheral vascular system. If a steel tube is used, it shall connply with ISO Round the calculated average water fiowrate to the nearest whole number of millilitres. This Indian Standard has been developed from Doc No.: Suggested colour references for opaque naaterials are given in annex C.

ISO 10555-5:1996

Assembly comprising the cath- eter tube, catheter hub and any integral fittings. When the needle is fully inserted into the catheter unit, the catheter tube shall neither extend beyond the heel of the needle bevel nor be nnore than 1 nnnn fronn it see dinnension a in figure 1. Search the history of over billion web pages on the Internet. Attention is particularly drawn to the following: Blood flow into the needle hub.

Other 105555-5 of this standard are as follows: The fluid pathway in the needle shall be free of unintended obstructions that would prevent flashback. Users of Indian Standards should ascertain that they are in possession of the latest amendments or edition by referring to the latest issue of ‘BIS Catalogue’ and ‘Standards: