KINGSPAN TF70 PDF

Kingspan Therma TF70 Floorboard; high performance insulation for floors with a continuous thermal performance, lasting a constructions life cycle. Kingspan TF70, TW55 and TP10 are readily available in the following product thicknesses 20mm, 25mm, 30mm, 40mm, 50mm, 60mm, 70mm, 75mm, 80mm. Thermafloor TF70 is a high performance, fibre free, rigid thermoset insulation core faced on both sides with a low emissivity composite foil facing which is used .

Author: Mojas Mazuran
Country: Venezuela
Language: English (Spanish)
Genre: Art
Published (Last): 26 February 2016
Pages: 433
PDF File Size: 17.5 Mb
ePub File Size: 19.57 Mb
ISBN: 784-5-79191-285-3
Downloads: 8778
Price: Free* [*Free Regsitration Required]
Uploader: Kill

The membrane should be brought up the surrounding foundation walls until it is sufficiently above the height of the wall DPC so that it wil connect with or form the DPC.

Contact our experienced technical services department today. Concrete slabs should be allowed to dry out fully prior to the installation of Kingspan Thermafloor Kingspa average 1 day per mm of slab thickness. TF70 is faced on both sides with a low emissivity composite foil facing which is highly resistant to the transmission of water vapour.

Kingspan TF70 Thermawall Rigid PIR Insulation Boards

Ensure the polythene sheet has mm overlaps, taped at the joints, and is turned up mm at the walls. Kingspan TF70 60mm, 5 x 1. If you do not click “Accept and close” but continue to use this website: The most popular board sizes may be available from stock. The surface of the slab should be smooth, flat and free from projections.

Ensure that safe methods of cleaning are used, as recommended by the suppliers of the spilt liquid.

The insulation core is resistant to short—term contact with petrol and with most dilute acids, alkalis and mineral oils. High performance rigid thermoset insulation — thermal conductivity 0.

  EDMUND CAMPION EVELYN WAUGH PDF

It used to insulate solid concrete and suspended timber ground floors, and has a thermal conductivity of 0. The project re-installs the original form of a 19th Century Courthouse. Pannal Water Tower Products from our Kooltherm and Therma ranges have helped to transform a derelict water tower in North Yorkshire into a striking family home.

Therma TF70 Floorboard

The concrete slab and screed should be allowed to dry out prior to the the installation of the floor finish. Click to download in a separate browser window. Underfloor Heating Systems Please refer to the instructions of the specific underfloor heating system manufacturer.

Order before 10am for next working day delivery. Adhesives containing such solvents should kungspan be used in association with this product. Presently there are no availability restrictions, apart from manufacturing lead-times and minimum quantity order levels on certain product sizes. If you do not click “Accept and close” but continue to use this website: Products from our Kooltherm and Therma ranges have helped to transform a derelict water tower in North Yorkshire into a striking family home.

Before the timber floor boards are interlocked, apply a continuous bead of waterproof wood grade PVA adhesive to the top and bottom of the tongue and groove joints. Method of test to determine the classification of the surface spread of flame of products Result – Class 1 rating. However, it is recommended that any spills be cleaned off fully before the boards are installed.

50mm Kingspan Thermafloor TF70 PIR Insulation Board | Floor Insulation

TF70, when subjected to Kingspn Standard fire tests, achieves the results given below. Measure the distance between the joists prior to cutting the boards as spacings can vary. The size of the battens selected should ensure that, when installed, the top surface of the insulation boards are flush with the top of the battens.

  APGENCO AE RESULTS 2012 PDF

Specifications Thermal conductivity 0.

Thermafloor® TF70 – Kingspan Insulation

Test – BS —3: Beam and block floors should be level and grouted. A thin sand blinding may be used to achieve a continuous level surface free from projections over rolled hardcore. The Model School Inchicore The Model School Inchicore is a conservation of and addition to a historic Irish primary school in order to adapt the school to modern day requirements. Please click “Accept and close” to accept the use tr70 cookies on our website. Kingspan K3 K3 superior performance phenolic boards for use in ground floors, or on supported or suspended concrete and timber floors.

If two layers of insulation are required, they should be horizontally offset relative to each other so that, as far as possible, the board joints in the two adjacent layers do not coincide with each other.

K3 superior performance phenolic boards for use in ground floors, or on supported or suspended concrete and timber floors. The subsequent installation of the concrete slab and screed or other flooring material is carried out in a manner similar to that for an un—insulated floor.

Modified to include board facings, the boards achieve a resistance far greater than MN.